Skip to content
Commit 10d00f78 authored by Christof Schmitt's avatar Christof Schmitt Committed by James Bottomley
Browse files

[SCSI] zfcp: Warn about storage devices with broken PLOGI data



After opening a remote port zfcp checks if the WWPN returned in the
PLOGI maches the WWPN of the port that should have been opened. On a
mismatch zfcp assumes that the DID just changed, queries the FC
nameserver and tries again. If the situation persists the erp will
give up.

With this strategy, if the remote port always returns the wrong PLOGI
data, the remote port will not be opened. Introduce a warning, so that
the system administrator knows why the remote port is not being opened
and to have a pointer to investigate the problem on the storage
system.

Reviewed-by: default avatarSwen Schillig <swen@vnet.ibm.com>
Signed-off-by: default avatarChristof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: default avatarJames Bottomley <James.Bottomley@suse.de>
parent 934aeb58