Commit 42fc191d authored by Matti Vaittinen's avatar Matti Vaittinen Committed by Lee Jones
Browse files

mfd: bd9576: Add safety limit/monitoring registers



ROHM BD9576 contains safety features like over/under voltage detection,
over curren detection and over temperature detection. Add the
configuration register information.

Signed-off-by: default avatarMatti Vaittinen <matti.vaittinen@fi.rohmeurope.com>
Signed-off-by: default avatarLee Jones <lee.jones@linaro.org>
parent e4560879
Loading
Loading
Loading
Loading
+19 −0
Original line number Diff line number Diff line
@@ -116,6 +116,25 @@ enum {
#define BD957X_REG_VOUT4_TUNE		0x59
#define BD957X_REG_VOUTL1_TUNE		0x5c

#define BD9576_REG_VOUT1_OVD		0x51
#define BD9576_REG_VOUT1_UVD		0x52
#define BD9576_REG_VOUT2_OVD		0x54
#define BD9576_REG_VOUT2_UVD		0x55
#define BD9576_REG_VOUT3_OVD		0x57
#define BD9576_REG_VOUT3_UVD		0x58
#define BD9576_REG_VOUT4_OVD		0x5a
#define BD9576_REG_VOUT4_UVD		0x5b
#define BD9576_REG_VOUTL1_OVD		0x5d
#define BD9576_REG_VOUTL1_UVD		0x5e

#define BD9576_MASK_XVD			0x7f

#define BD9576_REG_VOUT1S_OCW		0x5f
#define BD9576_REG_VOUT1S_OCP		0x60

#define BD9576_MASK_VOUT1S_OCW		0x3f
#define BD9576_MASK_VOUT1S_OCP		0x3f

#define BD957X_MAX_REGISTER		0x61

#endif