Commit 49c36dff authored by Jonathan Cameron's avatar Jonathan Cameron Committed by Greg Kroah-Hartman
Browse files

staging:iio:documentation pull a few sysfs entries out of main docs.



These two attributes are only used in the one driver.  Whilst they
are fairly general I'm not entirely happy committing to them at
this stage.

Signed-off-by: default avatarJonathan Cameron <jic23@kernel.org>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent 8dc24597
Loading
Loading
Loading
Loading
+0 −21
Original line number Diff line number Diff line
@@ -728,24 +728,3 @@ Contact: linux-iio@vger.kernel.org
Description:
		This attribute is used to read the amount of quadrature error
		present in the device at a given time.

What:		/sys/.../iio:deviceX/ac_excitation_en
KernelVersion:	3.1.0
Contact:	linux-iio@vger.kernel.org
Description:
		This attribute, if available, is used to enable the AC
		excitation mode found on some converters. In ac excitation mode,
		the polarity of the excitation voltage is reversed on
		alternate cycles, to eliminate DC errors.

What:		/sys/.../iio:deviceX/bridge_switch_en
KernelVersion:	3.1.0
Contact:	linux-iio@vger.kernel.org
Description:
		This attribute, if available, is used to close or open the
		bridge power down switch found on some converters.
		In bridge applications, such as strain gauges and load cells,
		the bridge itself consumes the majority of the current in the
		system. To minimize the current consumption of the system,
		the bridge can be disconnected (when it is not being used
		using the bridge_switch_en attribute.
+20 −0
Original line number Diff line number Diff line
What:		/sys/.../iio:deviceX/ac_excitation_en
KernelVersion:	3.1.0
Contact:	linux-iio@vger.kernel.org
Description:
		This attribute, if available, is used to enable the AC
		excitation mode found on some converters. In ac excitation mode,
		the polarity of the excitation voltage is reversed on
		alternate cycles, to eliminate DC errors.

What:		/sys/.../iio:deviceX/bridge_switch_en
KernelVersion:	3.1.0
Contact:	linux-iio@vger.kernel.org
Description:
		This attribute, if available, is used to close or open the
		bridge power down switch found on some converters.
		In bridge applications, such as strain gauges and load cells,
		the bridge itself consumes the majority of the current in the
		system. To minimize the current consumption of the system,
		the bridge can be disconnected (when it is not being used
		using the bridge_switch_en attribute.