Commit 55b5eb75 authored by Martin Schwidefsky's avatar Martin Schwidefsky
Browse files

s390/tape: remove redundant if statement



The unit check handler for 3480 / 3490 tapes used to print a different
warning message for erpa code 0x57 dependent on the device type.
The warning messages have been remove in a cleanup, the if statement
is a left over. Remove it.

Reported-by: default avatarFraser Brown <mlfbrown@stanford.edu>
Signed-off-by: default avatarMartin Schwidefsky <schwidefsky@de.ibm.com>
parent 926a7336
Loading
Loading
Loading
Loading
+5 −7
Original line number Original line Diff line number Diff line
@@ -773,13 +773,11 @@ tape_34xx_unit_check(struct tape_device *device, struct tape_request *request,
			"occurred\n");
			"occurred\n");
		return tape_34xx_erp_failed(request, -EIO);
		return tape_34xx_erp_failed(request, -EIO);
	case 0x57:
	case 0x57:
		if (device->cdev->id.driver_info == tape_3480) {
		/*
			/* Attention intercept. */
		 * 3480: Attention intercept.
			return tape_34xx_erp_retry(request);
		 * 3490: Global status intercept.
		} else {
		 */
			/* Global status intercept. */
		return tape_34xx_erp_retry(request);
		return tape_34xx_erp_retry(request);
		}
	case 0x5a:
	case 0x5a:
		/*
		/*
		 * Tape length incompatible. The tape inserted is too long,