Skip to content
Commit 6e35994d authored by Bharat Bhushan's avatar Bharat Bhushan Committed by Alexander Graf
Browse files

KVM: PPC: Use clockevent multiplier and shifter for decrementer



Time for which the hrtimer is started for decrementer emulation is calculated
using tb_ticks_per_usec. While hrtimer uses the clockevent for DEC
reprogramming (if needed) and which calculate timebase ticks using the
multiplier and shifter mechanism implemented within clockevent layer.

It was observed that this conversion (timebase->time->timebase) are not
correct because the mechanism are not consistent.
In our setup it adds 2% jitter.

With this patch clockevent multiplier and shifter mechanism are used when
starting hrtimer for decrementer emulation. Now the jitter is < 0.5%.

Signed-off-by: default avatarBharat Bhushan <bharat.bhushan@freescale.com>
Signed-off-by: default avatarAlexander Graf <agraf@suse.de>
parent cc902ad4