#define FTDI_SIO_SET_BREAK (0x1 << 14)
/* FTDI_SIO_SET_DATA */
/*
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
* bRequest: FTDI_SIO_SET_DATA
* wValue: Data characteristics (see below)
* wIndex: Port
* wLength: 0
* Data: No
*
* Data characteristics
*
* B0..7 Number of data bits
* B8..10 Parity
* 0 = None
* 1 = Odd
* 2 = Even
* 3 = Mark
* 4 = Space
* B11..13 Stop Bits
* 0 = 1
* 1 = 1.5
* 2 = 2
* B14
* 1 = TX ON (break)
* 0 = TX OFF (normal state)
* B15 Reserved
*
*/
/* FTDI_SIO_MODEM_CTRL */
#define FTDI_SIO_SET_MODEM_CTRL_REQUEST_TYPE 0x40
#define FTDI_SIO_SET_MODEM_CTRL_REQUEST FTDI_SIO_MODEM_CTRL
* BmRequestType: 0100 0000B
* bRequest: FTDI_SIO_MODEM_CTRL
* wValue: ControlValue (see below)
* wIndex: Port
* wLength: 0
* Data: None
*
* NOTE: If the device is in RTS/CTS flow control, the RTS set by this
* command will be IGNORED without an error being returned
* Also - you can not set DTR and RTS with one control message
*/
#define FTDI_SIO_SET_DTR_MASK 0x1
#define FTDI_SIO_SET_DTR_HIGH (1 | (FTDI_SIO_SET_DTR_MASK << 8))
#define FTDI_SIO_SET_DTR_LOW (0 | (FTDI_SIO_SET_DTR_MASK << 8))
#define FTDI_SIO_SET_RTS_HIGH (2 | (FTDI_SIO_SET_RTS_MASK << 8))
#define FTDI_SIO_SET_RTS_LOW (0 | (FTDI_SIO_SET_RTS_MASK << 8))
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
/*
* ControlValue
* B0 DTR state
* 0 = reset
* 1 = set
* B1 RTS state
* 0 = reset
* 1 = set
* B2..7 Reserved
* B8 DTR state enable
* 0 = ignore
* 1 = use DTR state
* B9 RTS state enable
* 0 = ignore
* 1 = use RTS state
* B10..15 Reserved
*/
/* FTDI_SIO_SET_FLOW_CTRL */
#define FTDI_SIO_SET_FLOW_CTRL_REQUEST_TYPE 0x40
#define FTDI_SIO_SET_FLOW_CTRL_REQUEST FTDI_SIO_SET_FLOW_CTRL
#define FTDI_SIO_RTS_CTS_HS (0x1 << 8)
#define FTDI_SIO_DTR_DSR_HS (0x2 << 8)
#define FTDI_SIO_XON_XOFF_HS (0x4 << 8)
/*
* BmRequestType: 0100 0000b
* bRequest: FTDI_SIO_SET_FLOW_CTRL
* wValue: Xoff/Xon
* wIndex: Protocol/Port - hIndex is protocl / lIndex is port
* Data: None
*
* hIndex protocol is:
* B0 Output handshaking using RTS/CTS
* 0 = disabled
* 1 = enabled
* B1 Output handshaking using DTR/DSR
* 0 = disabled
* 1 = enabled
* B2 Xon/Xoff handshaking
* 0 = disabled
* 1 = enabled
*
* A value of zero in the hIndex field disables handshaking
*
* If Xon/Xoff handshaking is specified, the hValue field should contain the XOFF character
/*
* FTDI_SIO_GET_LATENCY_TIMER
*
* Set the timeout interval. The FTDI collects data from the slave
* device, transmitting it to the host when either A) 62 bytes are
* received, or B) the timeout interval has elapsed and the buffer
* contains at least 1 byte. Setting this value to a small number
* can dramatically improve performance for applications which send
* small packets, since the default value is 16ms.
*/
#define FTDI_SIO_GET_LATENCY_TIMER_REQUEST FTDI_SIO_GET_LATENCY_TIMER
#define FTDI_SIO_GET_LATENCY_TIMER_REQUEST_TYPE 0xC0
* BmRequestType: 1100 0000b
* bRequest: FTDI_SIO_GET_LATENCY_TIMER
* wValue: 0
* wIndex: Port
* wLength: 0
* Data: latency (on return)
*/
* FTDI_SIO_SET_LATENCY_TIMER
*
* Set the timeout interval. The FTDI collects data from the slave
* device, transmitting it to the host when either A) 62 bytes are
* received, or B) the timeout interval has elapsed and the buffer
* contains at least 1 byte. Setting this value to a small number
* can dramatically improve performance for applications which send
* small packets, since the default value is 16ms.
*/
#define FTDI_SIO_SET_LATENCY_TIMER_REQUEST FTDI_SIO_SET_LATENCY_TIMER
#define FTDI_SIO_SET_LATENCY_TIMER_REQUEST_TYPE 0x40
* BmRequestType: 0100 0000b
* bRequest: FTDI_SIO_SET_LATENCY_TIMER
* wValue: Latency (milliseconds)
* wIndex: Port
* wLength: 0
* Data: None
*
* wValue:
* B0..7 Latency timer
* B8..15 0
*
*/
/*
*
* Set the special event character for the specified communications port.
* If the device sees this character it will immediately return the
* data read so far - rather than wait 40ms or until 62 bytes are read
* which is what normally happens.
*/
#define FTDI_SIO_SET_EVENT_CHAR_REQUEST FTDI_SIO_SET_EVENT_CHAR
#define FTDI_SIO_SET_EVENT_CHAR_REQUEST_TYPE 0x40
* BmRequestType: 0100 0000b
* bRequest: FTDI_SIO_SET_EVENT_CHAR
* wValue: EventChar
* wIndex: Port
* wLength: 0
* Data: None
*
* wValue:
* B0..7 Event Character
* B8 Event Character Processing
* 0 = disabled
* 1 = enabled
* B9..15 Reserved
*
*/
/* FTDI_SIO_SET_ERROR_CHAR */
/* Set the parity error replacement character for the specified communications port */
* BmRequestType: 0100 0000b
* bRequest: FTDI_SIO_SET_EVENT_CHAR
* wValue: Error Char
* wIndex: Port
* wLength: 0
* Data: None
*
*Error Char
* B0..7 Error Character
* B8 Error Character Processing
* 0 = disabled
* 1 = enabled
* B9..15 Reserved
*
*/
/* FTDI_SIO_GET_MODEM_STATUS */
/* Retrieve the current value of the modem status register */
#define FTDI_SIO_GET_MODEM_STATUS_REQUEST_TYPE 0xc0
#define FTDI_SIO_GET_MODEM_STATUS_REQUEST FTDI_SIO_GET_MODEM_STATUS
#define FTDI_SIO_CTS_MASK 0x10
#define FTDI_SIO_DSR_MASK 0x20
#define FTDI_SIO_RI_MASK 0x40
#define FTDI_SIO_RLSD_MASK 0x80
* BmRequestType: 1100 0000b
* bRequest: FTDI_SIO_GET_MODEM_STATUS
* wValue: zero
* wIndex: Port
* wLength: 1
* Data: Status
* B0..3 0
* B4 CTS
* 0 = inactive
* 1 = active
* B5 DSR
* 0 = inactive
* 1 = active
* B6 Ring Indicator (RI)
* 0 = inactive
* 1 = active
* B7 Receive Line Signal Detect (RLSD)
* 0 = inactive
* Offset Field Size Value Description
* 0 bLength 1 0x12 Size of descriptor in bytes
* 1 bDescriptorType 1 0x01 DEVICE Descriptor Type
* 2 bcdUSB 2 0x0110 USB Spec Release Number
* 4 bDeviceClass 1 0x00 Class Code
* 5 bDeviceSubClass 1 0x00 SubClass Code
* 6 bDeviceProtocol 1 0x00 Protocol Code
* 7 bMaxPacketSize0 1 0x08 Maximum packet size for endpoint 0
* 8 idVendor 2 0x0403 Vendor ID
* 10 idProduct 2 0x8372 Product ID (FTDI_SIO_PID)
* 12 bcdDevice 2 0x0001 Device release number
* 14 iManufacturer 1 0x01 Index of man. string desc
* 15 iProduct 1 0x02 Index of prod string desc
* 16 iSerialNumber 1 0x02 Index of serial nmr string desc
* 17 bNumConfigurations 1 0x01 Number of possible configurations
* Offset Field Size Value
* 0 bLength 1 0x09 Size of descriptor in bytes
* 1 bDescriptorType 1 0x02 CONFIGURATION Descriptor Type
* 2 wTotalLength 2 0x0020 Total length of data
* 4 bNumInterfaces 1 0x01 Number of interfaces supported
* 5 bConfigurationValue 1 0x01 Argument for SetCOnfiguration() req
* 6 iConfiguration 1 0x02 Index of config string descriptor
* 7 bmAttributes 1 0x20 Config characteristics Remote Wakeup
* 8 MaxPower 1 0x1E Max power consumption
* Offset Field Size Value
* 0 bLength 1 0x09 Size of descriptor in bytes
* 1 bDescriptorType 1 0x04 INTERFACE Descriptor Type
* 2 bInterfaceNumber 1 0x00 Number of interface
* 3 bAlternateSetting 1 0x00 Value used to select alternate
* 4 bNumEndpoints 1 0x02 Number of endpoints
* 5 bInterfaceClass 1 0xFF Class Code
* 6 bInterfaceSubClass 1 0xFF Subclass Code
* 7 bInterfaceProtocol 1 0xFF Protocol Code
* 8 iInterface 1 0x02 Index of interface string description
* Offset Field Size Value
* 0 bLength 1 0x07 Size of descriptor in bytes
* 1 bDescriptorType 1 0x05 ENDPOINT descriptor type
* 2 bEndpointAddress 1 0x82 Address of endpoint
* 3 bmAttributes 1 0x02 Endpoint attributes - Bulk
* 4 bNumEndpoints 2 0x0040 maximum packet size
* 5 bInterval 1 0x00 Interval for polling endpoint
* Offset Field Size Value
* 0 bLength 1 0x07 Size of descriptor in bytes
* 1 bDescriptorType 1 0x05 ENDPOINT descriptor type
* 2 bEndpointAddress 1 0x02 Address of endpoint
* 3 bmAttributes 1 0x02 Endpoint attributes - Bulk
* 4 bNumEndpoints 2 0x0040 maximum packet size
* 5 bInterval 1 0x00 Interval for polling endpoint
* The device reserves the first two bytes of data on this endpoint to contain the current
* values of the modem and line status registers. In the absence of data, the device
* generates a message consisting of these two status bytes every 40 ms
* Offset Description
* B0 Reserved - must be 1
* B1 Reserved - must be 0
* B2 Reserved - must be 0
* B3 Reserved - must be 0
* B4 Clear to Send (CTS)
* B5 Data Set Ready (DSR)
* B6 Ring Indicator (RI)
* B7 Receive Line Signal Detect (RLSD)
* Offset Description
* B0 Data Ready (DR)
* B1 Overrun Error (OE)
* B2 Parity Error (PE)
* B3 Framing Error (FE)
* B4 Break Interrupt (BI)
* B5 Transmitter Holding Register (THRE)
* B6 Transmitter Empty (TEMT)
* B7 Error in RCVR FIFO
*/
#define FTDI_RS0_CTS (1 << 4)
#define FTDI_RS0_DSR (1 << 5)
#define FTDI_RS0_RI (1 << 6)
#define FTDI_RS0_RLSD (1 << 7)
#define FTDI_RS_DR 1
#define FTDI_RS_OE (1<<1)
#define FTDI_RS_PE (1<<2)
#define FTDI_RS_FE (1<<3)
#define FTDI_RS_BI (1<<4)
#define FTDI_RS_THRE (1<<5)
#define FTDI_RS_TEMT (1<<6)
#define FTDI_RS_FIFO (1<<7)
/*
* OUT Endpoint
* This device reserves the first bytes of data on this endpoint contain the length
* and port identifier of the message. For the FTDI USB Serial converter the port
* identifier is always 1.
* Offset Description
* B0 Reserved - must be 1
* B1 Reserved - must be 0
* B2..7 Length of message - (not including Byte 0)