Skip to content
Commit 4a2d7882 authored by amy.shih's avatar amy.shih Committed by Guenter Roeck
Browse files

hwmon: (nct7904) Fix incorrect temperature limitation register setting of LTD.



According to kernel hwmon sysfs-interface documentation, temperature
critical max value, typically greater than corresponding temp_max values.
Thus, reads the LTD_HV_HL (LTD HIGH VALUE HIGH LIMITATION) and LTD_LV_HL
(LTD LOW VALUE HIGH LIMITATION) for case hwmon_temp_crit and
hwmon_temp_crit_hyst. Reads the LTD_HV_LL (HIGH VALUE LOW LIMITATION)
and LTD_LV_LL (LOW VALUE LOW LIMITATION) for case hwmon_temp_max
and hwmon_temp_max_hyst.

Signed-off-by: default avataramy.shih <amy.shih@advantech.com.tw>
Link: https://lore.kernel.org/r/20850618155720.24857-1-Amy.Shih@advantech.com.tw


Signed-off-by: default avatarGuenter Roeck <linux@roeck-us.net>
parent 7b1b68f0