pwm: stm32-lp: Add check in case requested period cannot be achieved



LPTimer can use a 32KHz clock for counting. It depends on clock tree
configuration. In such a case, PWM output frequency range is limited.
Although unlikely, nothing prevents user from requesting a PWM frequency
above counting clock (32KHz for instance):
- This causes (prd - 1) = 0xffff to be written in ARR register later in
the apply() routine.
This results in badly configured PWM period (and also duty_cycle).
Add a check to report an error is such a case.

Signed-off-by: default avatarFabrice Gasnier <fabrice.gasnier@st.com>
Reviewed-by: default avatarUwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: default avatarThierry Reding <thierry.reding@gmail.com>